thermostatic valve for solar water heater
1. Technical Data
DN15
a.Working pressure:0.03-1Mpa
b.Ideal working pressure:0.1-0.5Mpa
c.Maximum working temperature:≤99 C
d.Hot water inlet temperature range:50-99 C
e.Cold water inlet temperature range:5-29 C
f.Outlet Temperature range:35-45 C
g.Adjustment Accuracy:+/- 2 C
h.Rated outlet flow on 1 bar pressure drop : 0.7Cb.m./H (Same as 11.67L/Min)
Flow rate for pressure:
Pressure
(psi or kPa)
|
1 psi
|
5 psi
(34kPa)
|
10 psi
(69kPa)
|
15 psi
(103kPa)
|
20 psi
(138kPa)
|
30 psi
(207kPa)
|
Flow Rate
(liters per minute)
|
4.5
|
9
|
12.5
|
15.1
|
17.6
|
28.2
|
GPM
|
0.98
|
2.0
|
2.7
|
3.3
|
3.9
|
6.2
|
2.Materials of Construction
a.Valve body:DZR Brass P-CuZn40Pb2. Chromed Nickel.
b.Shutter:PPO
c.Spring:Stainless steel
d.O-ring:EPDM
e.Connection : Inlets-M, outlet-M