An overview of the
GJT - 320 - b type, suitable for thermal power plants, paper mills, cement and other large belt conveyor. Material for nonmagnetic material.
the technical indicators
1, the use of environmental conditions
Temperature: - 10 ℃ ~ + 40 ℃
Humidity: 45 ~ 75% RH (+ 25 ℃)
Working voltage: ~ 220 v + 10% for 50 hz
Power consumption: ﹤ 60 w
Instrument box size: 425 * 295 * 130 mm
Weight: instrument box 11 kg
2, function index
Sensitivity: a sample piece of Φ 30 mm, material speed: 1 ~ 3.5 m/s
Note: fast material for electrical iron iron ball
Time step is 1, 2, 3, 4, 6, 8, 10, 12, 14 seconds
Control output for normally open state of solid state relay (large metal control output is normally closed state)
3, installation conditions
Sensors installed base vibration amplitude st13 of 0.5 mm
Sensors installation ﹤ 18 ° Angle with the ground plane