Item Performance, Parameters
|
Measuring Principle
|
When the ultrasonic beam is transmitting in the liquid,its transmit time is proportional to the liquid flow
|
Application
|
for continuously measuring the flow of most clear,single and pure liquid which do not have large consistence suspended matter or bubbles.
|
Linearity
|
Better than 0.5%
|
Accuracy
|
Better than 1.0%
|
Repeatability
|
Better than 0.2%
|
Sensor Installation Method
|
Clamp-on
|
Measured Liquid
|
water, sea water, sewage, alcohol, various oils such as uniform, single, stable liquid
|
Display
|
backlit LCD can display instantaneous flow, cumulative flow, velocity, time, calories and other data signal output at the same time
|
Signal Input
|
Can input two current signals(such as: temperature, pressure, liquid level, etc. signals) in order to achieve heat measurements or a dual-purpose machine
|
Signal Output
|
electric current signal 4-20mA or 0-20mA, etc. Impedance 0 - 1K, accuracy 0.1%
|
OCT signal
|
positive and negative, the net cumulative flow and the heat cumulative pulse signal or the Instantaneous flow of the frequency signal.
|
Power Supply
|
220VAC(Standard) Battery: built-in Ni-MH accumulator which can work for more than 12hours continuously
|
Straight pipe length
|
Upstream≥10D,Downstream≥5D, Length from pump exit≥30D
|
Crust Materials
|
Die-casting aluminum
|
Other Features
|
Electric relay: Can output nearly 20 kinds of source signals (such as no signal, the reverse flow, etc.)
Sound Alarm: Can set the alarm buzzer sounds (such as the flow is max, or too small, etc.)
|