Quick Details
- Place of Origin: Hunan, China (Mainland)
- Model Number: TEC-O2
- Usage: Gas Sensor
- Theory: Current Sensor
- Output: Analog Sensor
Packaging & Delivery
Packaging Details: |
standard packing |
Delivery Detail: |
3-5 working days |
The toxic gas detection probe Overview:
TEC- series toxic gas sensor using imported electrochemical sensors and microprocessor control technology,
Module design uses a high-precision, low temperature drift precision amplifiers, power supply circuit with a stable ,low-noise design,signal processing have adopted low temperature drift and high precision device
Member, so that the module measurement high concentration stable, meantime in lower concentration detection high accuracy. at low concentrations measured by small interfering signals, provides high accuracy and stable of the measured data.
Features
adopted advanced imported electrochemical sensors, long life;
use high-precision op amps and power IC, stable, sensitive and reliable;
can accurately detect low or high concentrations of toxic gases;
product design, anti-interference ability, over-range protection, reverse polarity protection and lightning protection;
product design, low power consumption, network-based RS-485 output and digital TTL output
Probe selection table
Mode No
|
gas
|
range
|
Lower alarm value
|
High alarm value
|
TWA value
|
STEL value
|
unit
|
TEC-CO
|
CO
|
0-500 ppm
|
35
|
200
|
35
|
200
|
ppm
|
TEC-H2S
|
H2S
|
0-50ppm
|
10
|
15
|
10
|
15
|
ppm
|
TEC-NH3
|
NH3
|
0-100 ppm
|
25
|
50
|
25
|
35
|
ppm
|
TEC-SO2
|
SO2
|
0-20PPM
|
2
|
5
|
2
|
5
|
ppm
|
TEC-NO2
|
NO2
|
0-20PPM
|
3
|
5
|
5
|
5
|
ppm
|
TEC-CL2
|
Cl2
|
0-20 ppm
|
0.5
|
1.0
|
0.5
|
1.0
|
ppm
|
TEC-Br2
|
Br2
|
0-20 ppm
|
0.1
|
0.5
|
0.1
|
0.5
|
ppm
|
TEC-CLO2
|
ClO2
|
0-1 ppm
|
0.1
|
0.2
|
0.1
|
0.3
|
ppm
|
TEC-PH3
|
PH3
|
0-5 ppm
|
0.3
|
1.0
|
0.3
|
1.0
|
ppm
|
TEC-HCL
|
HCL
|
0-10 ppm
|
2.0
|
5.0
|
2.0
|
5.0
|
ppm
|
TEC-HBr
|
HBr
|
0-10 ppm
|
2.0
|
5.0
|
2.0
|
5.0
|
ppm
|
TEC-HCN
|
HCN
|
0-100ppm
|
4.7
|
10.0
|
4.7
|
10.0
|
ppm
|
TEC-H2O2
|
H2O2
|
0-100 ppm
|
1.0
|
3.0
|
1.0
|
3.0
|
ppm
|
TEC-ETO
|
ETO
|
0-20 ppm
|
1.0
|
5.0
|
1.0
|
5.0
|
ppm
|
TEC-CH2O
|
CH2O
|
0-5 ppm
|
0.1
|
.3
|
0.1
|
0.3 ppm
|
ppm
|
TEC-COCL2
|
COCL2
|
0-1 ppm
|
0.1
|
0.3
|
0.1
|
0.3
|
ppm
|
TEC-NO
|
NO
|
0-250ppm
|
25
|
50
|
25
|
50
|
ppm
|
TEC-SiH4
|
SiH4
|
0-20 ppm
|
2.0
|
5.0
|
2.0
|
5.0
|
ppm
|
TEC-O3
|
O3
|
0-5 ppm
|
0.1
|
0.3
|
0.1
|
0.3
|
ppm
|
TEC-H2
|
H2
|
0-1000ppm
|
200
|
500
|
200
|
500
|
ppm
|
TEC-O2
|
O2
|
0-25%
|
19.5
|
23.9
|
--
|
--
|
%
|
TEC-C2H4
|
C2H4
|
0-200 ppm
|
20
|
50
|
20
|
50
|
ppm
|
Technical Parameter
Detect gas
|
See the probe selection
|
Principle
|
Electrochemical- sensor
|
Installation method
|
Diffused type
|
Response time
|
30 S~40 S( the response of the sensor)
|
accuracy
|
≤±3%FS
|
repeatability
|
≤±2%
|
Linear error
|
≤±2%
|
Zero drift
|
≤±2%(F.S/year)
|
Operated temperature
|
-40~80℃
|
humidity
|
15-95%RH (Non-condensing)
|
Sensor working temperature
|
-40℃-50℃
|
Sensor working humidity
|
15-90%RH (Non-condensing)
|
signal output
|
network:RS-485
digital:TTL
|
Operated voltage
|
DC 5.5 V
|
Application for the Probe
Petroleum, petrochemical, metallurgy, chemical, fire, gas, environmental protection, power, telecommunications, paper, printing and dyeing, sewage treatment, food and brewing,
Research, education, national defense