Touch Screen Fetal/Maternal Monitor CTG Belt - Exportimes.com

Supplier Details

Taian Medi Medical Electronic Co., Ltd.  

Year Established:1998

Business Type:Manufacturer, Trading Company

Management Certifiation:

Operational Address:
Zone A-8, Taishan Tech City, High And New Technology Industrial Development Zone, Tai'an, Shandong, China (Mainland)

Touch Screen Fetal/Maternal Monitor CTG Belt

Touch Screen Fetal/Maternal Monitor CTG Belt
  • Touch Screen Fetal/Maternal Monitor CTG Belt
Share to:

FOB Price: US $ 600 - 5,000 / Set; Min.Order Quantity: 3 Set/Sets; Supply Ability: 10 Set/Sets per Day; Port: depends; Payment Terms: L/C,T/T,Western Union.

Product Details

Parameter

Model Number : MD2000C
Place of Origin : Shandong, China (Mainland)
Brand Name : MEDI
Type : Maternal-Neonatal Ultrasonic Monitor
Ultrasound Frequency : 1.0MHz
Ultrasound Launching Way : DSP
Power : <5mW/cm2
Fetal Movement : 40-220BPM
Uterine Pressure : 0-100 relative strength
Twins Monitoring : Optionable
Priter : 50mm Or 112mm Thermal paper printer
Screen : 12.1'TFT Touchable
Monitoring Content : FM TOCO FHR
Controlings : Shuttle Mouse and buttons and touching screen

Description

MD2000C Computer Automatic Rea-time Online Analytical Maternal-Neonatal Monitor 

Computer Automatic Real-time On-line Analytical Function 

This function have get our National Invention Patents . 

 

 

2000C Computer Automatic Real-time On-line Analytical Maternal-Neonatal Monitor , have two monitoring interface . 

 Pregnant women & Fetal Monitoring together , Fetal Monitoring two kinds . 

 The pregnant women & fetal monitoring , except the FHR , FM & TOCO monitoring , also will monitoring the pregnants'RESP , HR , SPO2 , HIBP , PR , TMP . 

 The fetal monitoring interface , monitoring the FHR , FM & TOCO especially , not only can shows the FHR , FM & TOCO Curves , but also give the Real-time On-line Analytical Results , the monitoring will given in the same screen . 

 

 From the above photos , we can see that our products is truly realize the automatic diagnosis of fetal monitoring , make each of obstetrics and gynecology doctors can analysis and diagnosis of fetal monitoring graphics easily and accurately.

 On the fetal monitoring graphics, it can shows the fetal heart rate baseline,accelerated change, deceleration change, the situation of variation , the change of uterine contraction , fetal movement , various parameters changes , then shows on the screen .After the monitoring , the conclusion and score is given automatically . 

 

 So our Computer Automatic Real-time On-line Analytical Function has the advantages of Real-time , Process , Parameters and Comprehensive . 

 

 

 

1.0 MHz Digital Pulse Ultrasonic Broadband Technology >>>

This technology have get our National Invention Patents . 

 

For our products , it has the function of Computer Automatic Real-time On-line Analytical , we adopt the 1.0MHz Digital Pulse Ultrasonic Broadband Technology , have get our National Paten . The message below is the advantages of our this technology .

 

1.Wide Sound Beam . Made the machine has a wide range of fetal heart caputre. Fetal heart capture is not affected by the fetal movement and uterine contraction effect . 

 

2.Adopt the DSP technology , make the machine strng anti-jamming capability ,almost zero moise . 

 

3.Adopt the 1.0MHz Digital Pulse Ultrasonic Broadband Technology , the attenuation is small , strong echo , high sensitivity , easy to capture the fetal heart . 

 

4.Stable performance , Realiable quality . 

 

 


 
 

 

MD2000C Computer Automatic Rea-time Online Analytical Maternal-Neonatal Monitor 

 

            FHR Ultrasonic Frequency and the way: 1.0MHz,12 chips,digital pulse ultrasonic broadband
Measurement Range : 40-220BPM
Accuracy : Within ±1BPM
Fetal Heart Voice : 1-8 degree , Adjustable 
           TOCO Record Range : 1-100 relative unit
Non-line Error : ‹±10%
          Fetal Movement Automatic Fetal Movement Mark
                      Sp02 Measurement Range : 50% - 100%
Accuracy : Within70% - 100% , ‹±4%
                      PR Measurement Range: 30-240t/min
Accuracy : Within ±10%
                        Temp Temp Unite : °c
Temp Measurement Range : 26-45°c
Temp Measurement Accuracy : Within ±0.2°c

               ECG

Lead Mode : 3-lead,  I/II/III  :  5-lead:  I/II/III /AVR/AVL/V
HR Measurement Range : 15-300bpm
HR Alarm Limit and Accuracy:Upper Limit:60-300BPM,Accuracy:±10%                                                                                         Inferior Limit:10-200BPM,Accuracy:±10%
Alarm Time : Since the heart rate, out-of-limit occurs to the time of the alarm is less than 12s
HR Measurement Accuracy : 1BPM or ±1% , Either the maximum value of .
Frequency Response: Filer Way:1-25Hz              Non-filer:0.5-100Hz
Waveform Scanning Speed : 6.25mm/s , 12.5mm/s , 25mm/s , 50mm/s 
Waveform Scanning Speed Accuracy: ≤±10%
Defibrillation Recovery Time: ‹5s (Monitor or Operation Mode)
ECG Measurement Range : When the standard sensitivity , the heart rate measurement signal range is ±0.5mV ~ ±3mV
The Standard Signal Accuracy : 1mV±5%
                        NIBP Oscillometry
Mode:Mannual / Automatic
Unite: mmHg , kpa

Measurement Range: SBP:40mmHg - 250mmHg(5.3kpa-33.25kpa)

                                   DBP:20mmHg - 220mmHg(2.66kpa - 29.26kpa)

                                   MAP:30mmHg - 240mmHg(3.99kpa - 31.92mmHg)

Measurement Accuracy : ‹ ±10% , or ±0.5kpa(±3.75mmHg) , Either the maximum value of 

 

 

 

Company Profile

Taian Medi Medical Electronics Co.,Ltd is professional in fetal monitor, maternal and fetal monitor,muti-parameter monitor, central monitoring system and remote medical monitoring network system of research and development , production and clinical training of high-tech enterprises .

The company has an excellent R&D team covering electronics, computer , medical image processing , medical monitoring . In 2011 was identified as software enterprises, own Shandong Province engineering research center for remoter medical monitoring . Has obtained two national invention patents, nine utility model paternts, four software copyright .

The technologh research and development by our company , "Automatic Analysis of the Real-time Online Computer Fetal Maternal and Infant Monitor", has abtained Shandong Province Depatment of Technology Innnovation Fund Project in 2010, and in 2011 won the State Ministry of Science and Technology Innovation Fund Projects . This product has solved the obsterics and gynecology medical staff generally do not understand the fetal monitoring graphics analysis of diagnosis, greatly promoted the development and the clinical application of the fetal monitoring .

Company research and development of the wireless remote from the central monitoring network system, include in the Shandong Province Science and Technology Development by the Science Research Project in 2011, in 2011 was classified as provincial strategic emerging industries in Shandong Province People's Government, in 2012 by Taian Government as Taian Key Engineering Projects.

Post Buying Request

  • * Title:Please input title
  • * Message:Please input message
  • Your message must be between 20-8000 characters
  • * Your Email Address:Please input Email
  • Your email is also your login ID

You May Be Interested In

辽ICP备09008998号-11 ICP许可证号:辽B-2-4-20110169. Copyright Notice © 2016-2021 Liaoning MEC Group Co., Ltd. All rights reserved.