Product id: 266 goods in detail:
Product features:
1. Small size, light weight, because of using the latest electronic devices and digital signal processing technology, make the instrument is now 30% smaller than the original, a 30% reduction in weight.
2. The battery can work continuously for 12 hours
Applicable range: 3. Sensor Φ 13 ~ Φ 6000 mm
4. High precision, fast response speed, plus or minus 1.0% accuracy, response time less than a second.
5. High bubble: USES the digital signal processing technology has greatly increased the bubble resistance
6. Reliable performance, easy operation, large screen LCD display easy reading, narrowing the function keys to select interface, set up is simple, the waterproof performance is superior.
7. The large capacity SD memory card: the measurement data can be stored in the SD card
8. USB serial communication interface
9. Heat (heat value) measurements: through temperature measurement heat input, easy to cold, heat capacity management.
10. Drawing printer connection (optional) : adaptation composite printer
11. The velocity of measurement (optional) : can be real-time display fluid distribution
Technical parameters:
project
Conditions, performance and parameters
Apply to the fluid
Water, hot water, distilled water, wine, emulsion, such as ethanol ultrasonic can through homogeneous liquid
Apply pipe inner
13 mm ~ 6000 mm Φ Φ (determined by the sensor)
By measurement of body temperature
- 40 ~ 200 ℃ (determined by the sensor type)
Determination of the velocity
0 ~ + 32 m/s (minimum + / - 0.3 m/s)
Measurement accuracy
The velocity of plus or minus 1.0%
Operation, output cycle
1 second
line
The propagation time difference way (1 line)
display
Color LCD with backlight
Analog signal output
DC4 ~ 20 ma (1)
Analog signal input
DC4 ~ 20 ma/DC1 ~ 5 v (2 points)
The power supply voltage
Internal battery (fully charged continuous work for 12 hours)
Protection grade
IP64
Overall dimensions
210 x 120 x 65 mm (excluding printer)
The weight of the
1 kg
SD card
256 MB can store data in a year
Serial communication
Use USB port to transmit data (stored in the SD card is instantaneous flow and cumulative amount) transmission distance: 3 m
function
Damping time constant (0 ~ 100 seconds)
The instantaneous flow display (10) can be set all kinds of flow unit
The cumulative amount of display (10) can set all kinds of flow unit
heat
Measuring the diagnosis (low battery voltage, according to the receiving wave)
Flash memory (pipes, fluid, the parameters of the probe, etc)
Login address up to 32
Zero adjustment (to be automatic/manual)
The forward and reverse flow measurement
Low flow resection (0 ~ 5 m/s)
Optional components
Printer: print display shows images of timing print, recorder data in the print
Way of doppler velocity distribution show that the instantaneous flow and average velocity distribution