Packaging & Delivery
Packaging Details: |
carton package according to the requirement of our customers |
Delivery Detail: |
within 1 to 2 month according the order amount |
Specifications
Profibus-Modbus protocol gateway
1.Provide communication ability to MODBUS device
2.Supports TTL level, RS485, RS232
Microcyber NCS-MP105 industrial Profibus-Modbus protocol gateway
Model No. G0307 Model No. NCS-MP105
G0307 is PROFIBUS /MODBUS protocol gateway, the address of the PROFIBUS-PA slave, MODBUS RTU master. It's a new product of our company and will be put onto the market soon.
NCS-MP105 is PROFIBUS / MODBUS converting module, also with the address of the PROFIBUS-PA slave, MODBUS RTU master.
Product Description
- NCS-MP105 is converter for interfacing Modbus- RTU instruments to a Profibus PA network.
- Support PROFIBUS DPV1 and PROFIBUS PA 3.01
- Support AI, AO, DI, DO standard function blocks
- Support GSD5.0 and standard EDD
- Support standard DD or EDD specification
- Electrical interface connected with MODBUS device supports TTL level, RS485 and RS232
- Able to provide 3.3V or 5V power supply output
NCS-MP105 is a converter device for MODBUS- RTU protocol to PROFIBUS PA protocol. It is able to integrate device/board with MODBUS communication interface to PROFIBUS PA bus system. Bus power supply is selected by NCS-MP105, and NCS-MP105 can provide power supply to the boards the user provides.
As a MODBUS host, NCS-MP105 communicates with the device with MODBUS-RTU interface, it can achieve read/write operation for MODBUS register data via PA transducer blocks, and convert MODBUS data to PA communication system via PA standard AI,AO,DI,DO function blocks.
NCS-MP105 Application:
- Gas detectors
- Analyzers
- Positioners
- Any smart device with MODBUS protocol
Physical Parameters
Bus signal: compliant with IEC61158-2 physical layer standard
Bus power supply: 9 ~ 32V
Operating temperature: -40 ~ 85°C
Static current: ≤14mA
Humidity range: 5% ~ 95%,non-dew
Mechanism size: diameter 66mm(can be customized)
Supportive MODBUS Communication Parameters
Address: 1 ~ 255
Baud rate: 9600 / 19200 / 15625 / 31250 /62500 / 125000 bps
Data bit: 7 / 8 bits
Calibration: odd / even calibration
Stop bit: 1 / 2 bits
CRC calibration: low byte ahead / high byte ahead
Data format: support various data formats
Supportive MODBUS Function Code
Function Code 1: read loop status
Function Code 2: read discrete input status
Function Code 3: read keeping register value
Function Code 4: read input register value
Function Code 6: write loop
Function Code 16:write multiple register values